LXDG-15~25
Metrological Requirements
Temperature class: for cold water T30, for hot water T30/90
Water pressure class: MAP10 or MAP 16 on request.
Pressure-loss class: △p63
Sensitivity to the irregularity in the upstream velocity fields class; U10
Sensitivity to the irregularity in the downstream velocity fields class; D5
Maximum Permissible Error
a) In the lower zone (Q1≤Q﹤Q2)±5%
b) In the upper zone (Q2≤Q≤Q4); for water temperature up to 30°C±2% from 30°C up to 90°C ±3%
Applications: to record the total volume of water passed through the pipelines.
Characteristics: compact design, light weight, magnet transmission register which could be rotation in 360 for convenient reading.
Note:
1. The water meter complies with the standard of<<GB/T 778.1-3-2007>> (ISO 4064-1-3:2005, IDT).
2. For hot water up to 90C is available on request.